WARDS NATURAL SCIENCE ESTABLISHMENT INC -- 2,6-DICHLOROINDOPHENOL, SODIUM SALT -- -
=====================  Product Identification  =====================

Product ID:2,6-DICHLOROINDOPHENOL, SODIUM SALT
MSDS Date:02/22/1999
FSC:NIIN:Submitter:D DG
Status Code:A
Kit Part:Y
=== Responsible Party ===
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692
Country:US
Info Phone Num:(716) 359-2502 OR 800-962-2660
Emergency Phone Num:716-359-2502 800-424-9300
Resp. Party Other MSDS Num.:MSDS NO. IX51-3
Preparer's Name:MICHAEL RASZEJA
Chemtrec Ind/Phone:(800)424-9300
CAGE:63759
=== Contractor Identification ===
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692-9012
Country:US
Phone:(716) 359-2502
Contract Num:MDA414-01-P-0094
CAGE:63759
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692-9012
Country:US
Phone:(716) 359-2502
Contract Num:MDA414-01P-0022
CAGE:63759
Company Name:WARDS NATURAL SCIENCE ESTABLISHMENT INC
Address:5100 W HENRIETTA RD
Box:92912
City:ROCHESTER
State:NY
ZIP:14692-9012
Country:US
Phone:(716) 359-2502
Contract Num:MDA414-01P-0092
CAGE:63759

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLOROINDOPHENOL, SODIUM SALT
CAS:620-45-1
RTECS #:GU5495000
= Wt:99.

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NO DATA PROVIDED BY MANUFACTURER
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MAY BE HARMFUL BY INHALATION,
    INGESTION, OR SKIN ABSORPTION. MAY CAUSE GASTROINTESTINAL
    DISTURBANCES. MAY CAUSE EYE IRRITATION. EXERCISE APPROPRIATE
    PROCEDURES TO MINIMIZE POTENTIAL HAZARDS.
Explanation of Carcinogenicity:NO DATA PROVIDED BY MANUFACTURER
Effects of Overexposure:MAY BE HARMFUL BY INHALATION, INGESTION, OR
    SKIN ABSORPTION. MAY CAUSE GASTROINTESTINAL DISTURBANCES. MAY CAUSE
    EYE IRRITATION. EXERCISE APPROPRIATE PROCEDURES TO MINIMIZE
    POTENTIAL HAZARDS.
Medical Cond Aggravated by Exposure:NO DATA PROVIDED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES,
    LIFTING UPPER AND LOWER EYELIDS OCCASIONALLY. IF IRRITATION OCCURS
    GET MEDICAL ATTENTION. INGESTION: IF SWALLOWED, IF CONSCIOUS, GIVE
    ONE OR  TWO GLASSES OF WATER TO DRINK AND CALL PHYSICIAN. NEVER
    GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. INHALATION: REMOVE
    TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF
    BREATHING IS  DIFFICULT, GIVE OXYGEN. GET MEDICAL ATTENTION. SKIN:
    FLUSH THOROUGHLY WITH SOAP AND WATER.

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Extinguishing Media:CARBON DIOXIDE (CO2); DRY CHEMICAL (ABC); WATER
    SPRAY.
Fire Fighting Procedures:IN FIRE CONDITIONS, WEAR A NIOSH/MSHA-APPROVED
    SELF-CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY PRODUCE
    HAZARDOUS DECOMPOSITION PRODUCTS. CAN REACT VIGOROUSLY WITH
    OXIDIZING MATERIALS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:AVOID MAKING DUST, SWEEP UP AND PLACE IN A
    SUITABLE CONTAINER FOR PROPER DISPOSAL. FLUSH SPILL AREA WITH
    WATER, THEN WASH WITH SOAP AND WATER.
Neutralizing Agent:NO DATA PROVIDED BY MANUFACTURER

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY,	PLACE, AWAY
    FROM OXIDIZING MATERIALS. WASH THROUGHLY AFTER HANDLING.
Other Precautions:HYGROSCOPIC. USE WITH ADEQUATE VENTILATION. REMOVE
    AND WASH CONTAMINATED CLOTHING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NEEDED IN NORMAL LABORATORY HANDLING. WEAR
    A NIOSH/MSHA-APPROVED DUST MASK IF DUSTY CONDITIONS PREVAIL.
Ventilation:LOCAL/MECHANICAL (GENERAL) EXHAUST RECOMMENDED.
Protective Gloves:RUBBER
Eye Protection:CHEMICAL SAFETY GLASSES.
Other Protective Equipment:GOGGLES, SMOCK, APRON, EYE WASH STATION,
    VENTILATION HOOD, AND PROPER GLOVES. .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:DECOMPOSES
Melt/Freeze Pt:M.P/F.P Text:NONE LISTED
Vapor Pres:NEGLIGIBLE AS SOLID.
Vapor Density:NOT DETERM
Spec Gravity:>1
Solubility in Water:FREELY SOLUBLE IN WATER
Appearance and Odor:DARK GREEN-BLACK POWDER; NO ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:STABLE. EXCESSIVE TEMPERATURE OR HEAT.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION, EMITS
    TOXIC FUMES OF CHLORINE AND OXIDES OF NITROGEN AND SULFUR, OXIDES
    OF CARBON.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

===================  Toxicological Information	===================

Toxicological Information:NO DATA PROVIDED BY MANUFACTURER

=====================  Ecological Information  =====================

Ecological:NO DATA PROVIDED BY MANUFACTURER

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
    TO FEDERAL, STATE, OR LOCAL LAWS. THESE DISPOSAL GUIDELINES ARE
    INTENDED FOR THE DISPOSAL OF CATALOG-SIZE QUANTITIES ONLY. DISPOSE
    OF IN AN APPROVED IN CINERATOR EQUIPPED WITH AN AFTERBURNER AND
    SCRUBBER OR DISPOSE OF IN AN APPROVED CHEMICAL LANDFILL.

===================  MSDS Transport Information  ===================

Transport Information:NON-REGULATED.

=====================  Regulatory Information  =====================

SARA Title III Information:NO DATA PROVIDED BY MANUFACTURER
Federal Regulatory Information:NO DATA PROVIDED BY MANUFACTURER
State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.